Resetting the power supply
If an overload triggers the power supply overload protection, all power is immediately disconnected. To
reset the power supply:
1. Disconnect the power cord from the workstation..
2. Determine what caused the overload and fix the problem. See
System diagnostics and
troubleshooting on page 109 for troubleshooting information.
3. Reconnect the power cord and reboot the workstation.
When you power off the workstation through the operating system, power consumption falls below what
is considered low power consumption, but does not reach zero. This low power consumption feature
extends the life of the power supply.
Environmental specifications
This section describes the environmental specifications of your workstation.
Table 1-14 Environmental specifications
Temperature (operating) 5° to 35°C (40° to 95°F)
Temperature (nonoperating) -40° to 60°C (-40° to 140°F)
Humidity (operating) 8% to 85% RH, noncondensing
Humidity (nonoperating) 8% to 90% RH, noncondensing
Altitude (operating) 0 to 3,048m (10,000 ft)
Altitude (nonoperating) 0 to 9,144m (30,000 ft)
Shock (operating) 1/2-sine: 40G, 2–3 ms
Shock (nonoperating) 1/2-sine: 160 cm/s, 2–3 ms (~100g)
Square: 20G, 422 cm/s
NOTE: Values represent individual shock events and are not
indicative of repetitive shock events.
Vibration (operating) Operating random: 0.5G (rms), 5–300 Hz
Vibration (nonoperating) Random: 2.0G (rms), 10–500 Hz
NOTE: Values are not indicative of continuous vibration.
12 Chapter 1 Product overview ENWW