Scope commands
Copyright © Itech Electronic Co., Ltd. 90
Chapter10 Scope commands
SCOPe:VOLTage:RANGe
This command sets the voltage range of oscilloscope function.
Model
Voltage range of oscilloscope function
IT6411
0.1/0.2/0.5/1/2/5/10
IT6411S
0.1/0.2/0.5/1/2/5/10
IT6431
0.1/0.2/0.5/1/2/5/10
IT6432
0.1/0.2/0.5/1/2/5/10
IT6433
0.2|0.5|1|2|5|10|20
IT6432S
0.1/0.2/0.5/1/2/5/10
Command syntax
SCOPe:VOLTage:RANGe < NRf >
Arguments
< NRf >
Unit
V
Example
SCOP:VOLT:RANG 1
Query syntax
SCOPe:VOLTage:RANGe?
Returns
<NRf>
SCOPe:CURRent:RANGe
This command sets the current range of oscilloscope function.
Model
Current range of oscilloscope function
IT6411
0.005/0.01/0.02/0.05/0.1/0.2/0.5/1/2
IT6411S
0.0001|0.0002|0.0004|0.001|0.002|0.004|0.01|0.02|0.04
IT6431
0.01/0.02/0.05/0.1/0.2/0.5/1/2/5