EasyManua.ls Logo

ITech IT6400 Series - Battery:total <Nrf; Battery:paramneter <Nrf><Nrf><Nrf; Battery:voltage:shut <Nrf

ITech IT6400 Series
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Battery commands
Copyright © Itech Electronic Co., Ltd. 102
BATTery:TOTal <NRf>
This command sets the total point of the current group of BATTERY.
Command syntax
BATTery:TOTal< NRf >
Arguments
0-19
Example
BATTery:TOTal 1
Query syntax
BATTery:TOTal?
Returns
<NR1>
BATTery:PARamneter <NRf><NRf><NRf>
This command sets the 3 parameters of the current point of the current group,
i.e., capacity, voltage and internal resistance.
Command syntax
BATTery:PARameter< NRf >
Arguments
Capacity,Volt,Res
Example
BATTery:PARameter 100,5,0.01
Query syntax
BATTery:PARameter?
Returns
<NRf>,<NRf>,<NRf>
BATTery:VOLTage:SHUT <NRf>
This command sets the voltage shut-off value of BATTERY.