Output command
Copyright © Itech Electronic Co., Ltd. 65
[SOURce:]DIGital:FUNCtion
This command configures two control ports and saves them in NVM.
RIDFi configured as discrete error interruption.
DIGio configured as digital output port. (Refer to DIG:DATA)
Command syntax
[SOURce:]DIGital:FUNCtion <CRD>
Arguments
RIDFi | DIGio
Example
DIG:FUNC DIG
Query syntax
[SOURce:]DIGital:FUNC?
Returns
<CRD>
[SOURce:]CURRent:LIMit:STATe
This command sets the source OCP state. Parameters include 1, 0, ON and
OFF, Parameters include 0|1|ON|OFF.
Command syntax
[SOURce:]CURRent:LIMit:STATe <bool>
Arguments
0|1|ON|OFF
Example
CURR:LIM:STAT 1
Query syntax
[SOURce:]CURRent:LIMit:STATe?
Returns
0|1