EasyManua.ls Logo

ITech IT6400 Series - Trigger:sequence2:Source; Trigger:acquire:source; Trigger:sequence:mode; Trigger:acquire:mode

ITech IT6400 Series
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Trigger commands
Copyright © Itech Electronic Co., Ltd. 83
TRIGger:SEQuence2:SOURce
TRIGger:ACQuire:SOURce
These commands select the trigger source for measurement triggers as
follows:
BUS GPIB device, *TRG, or <GET> (Group Execute Trigger)
INTernal trigger is generated internally when the measured waveform
crosses the trigger level with the selected slope.
EXTernal Selects the external trigger input
Command syntax
TRIGger:SEQuence2:SOURce<source>
TRIGger:ACQuire:SOURce<source>
Arguments
BUS | INTernal|EXTernal
RSTValue
INTernal
Example
TRIG:ACQ:SOUR BUS
Query syntax
TRIGger:SEQuence2:SOURce?
TRIGger:ACQuire:SOURce?
Returns
<CRD>
TRIGger:SEQuence:MODE
TRIGger:ACQuire:MODE
This command sets the internal voltage trigger mode. Parameters include
AUTo|NORMal|SINGel, i.e., automatic, normal and single modes.
Command syntax
TRIGger:SEQuence:MODE

Table of Contents

Other manuals for ITech IT6400 Series