Scope commands
Copyright © Itech Electronic Co., Ltd. 95
IT6433
-30V~ +60V
IT6432S
-30V~ +30V
Command syntax
SCOPe:DVM:BASE < NRF >
Arguments
< NRF >
RST Value
0
Example
SCOP:DVM:BASE 0
Query syntax
SCOPe:DVM:BASE?
Returns
<NRF>
SCOPe:VOLTage:TRIGer
This command sets the voltage trigger level of oscilloscope function.
Model
The setting range of voltage trigger level
IT6411
-15.1V ~ +15.1V
IT6411S
-15.1V ~ +15.1V
IT6431
-15.1V ~ +15.1V
IT6432
-30.1V ~ +30.1V
IT6433
-60.1V ~ +60.1V
IT6432S
-30.1V ~ +30.1V
Command syntax
SCOPe:VOLTage:TRIGer < NRF >
Arguments
< NRF >