Remote Control
Copyright © Itech Electronic Co., Ltd. 6
NOTE
As for every SCPI message with one query sent to the instrument, the
instrument will use a <NL> or newline sign (EOI) to terminate response of
return. For example, if "DISP:TEXT?" is sent, <NL> will be placed after the
returned data string to terminate response. If an SCPI message includes
several queries separated by semicolon (such as "DISP?;DISP:TEXT?"),
<NL> will terminate response returned after response to the last query. In
all cases, the program must read <NL> in response before another
command is sent to the instrument, otherwise errors will be caused.
1.5 Data Type
SCPI language defines several data types used for program message and
response messages.
Numerical parameter
Commands requiring numerical Parameter support the notations of all common
decimal notations, including optional signs, decimal points, scientific notation,
etc. Special values of numerical Parameter are also acceptable, such as MIN,
MAX and DEF. In addition, suffixes for engineering units can also be sent
together with numerical Parameter (including M, k, m or u). If the command
accepts only some specific values, the instrument will automatically round the
input Parameter to acceptable values. The following commands require
numerical Parameter of frequency value:
[SOURce[1|2]:]FREQuency:CENTer {<Frequency>|MINimum|MAXimum}
Discrete parameter
Discrete Parameter are used for settings with limited number of programming
values (such as IMMediate, EXTernal or BUS). They can use short and long
format like key words of commands. They may be expressed in both upper and
lower case. The query response always returns uppercase Parameter in short
format. The following commands require discrete Parameter in voltage unit:
[SOURce[1|2]:]VOLTage:UNIT {VPP|VRMS|DBM}
Boolean parameter
Boolean Parameter refer to true or false binary conditions. In case of false
conditions, the instrument will accept "OFF" or "0". In case of true conditions,
the instrument will accept "ON" or "1". In query of Boolean settings, the
instrument will always return "0" or "1". Boolean Parameter are required by the
following commands:
DISPlay {OFF|0|ON|1}
ASCII string Parameter
String Parameter may actually include all ASCII character sets. Character
strings must start and end with paired quotation marks; and single quotation
marks or double quotation marks are both allowed. Quotation mark separators

Table of Contents

Other manuals for ITech IT6400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6400 Series and is the answer not in the manual?

ITech IT6400 Series Specifications

General IconGeneral
BrandITech
ModelIT6400 Series
CategoryPower Supply
LanguageEnglish

Related product manuals