Trace Commands
Copyright © Itech Electronic Co., Ltd. 87
Arguments
VOLTage|CURRent|TWO
Example
TRAC:FEED VOLT
Query syntax
TRACe:FEED?
Returns
<CRD>
TRACe:FEED:CONTrol
This command sets the storage mode of data cache, Including Always (FIFO,
first in and first out of data in the buffer area), Next (Repetition, enable write
protection till the buffer area is full) and Never (OFF, disable write protection for
the buffer area).
Command syntax
TRACe:FEED:CONTrol<CRD>
Arguments
ALWays|NEXT|NEVer
Example
TRACe:FEED:CONTrol ALWays
Query syntax
TRACe:FEED:CONTrol?
Returns
< CRD > ALWays|NEXT|NEVer
TRACe:STATistics
This command sets the variable type of data cache. Parameters include
mean/peak/max/min, i.e., mean value, peak-peak value, maximum value and
minimum value.
Command syntax
TRACe:STATistics<CRD>