EasyManua.ls Logo

ITech IT6400 Series - [Source:]Voltage:trigger

ITech IT6400 Series
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Output command
Copyright © Itech Electronic Co., Ltd. 70
Example
VOLT:PROT:STAT 1
Query syntax
[SOURce:]VOLTage:PROTection:STATe?
Returns
0|1
[SOURce:]VOLTage:TRIGger
This command sets a preset voltage value for source. This preset value will be
promptly transferred to output if a trigger is generated. To generate trigger, the
trigger subsystem must be initialized (in trigger subsystem, INITiate command
is used for initialize trigger).
Command syntax
[SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude]
Arguments
<NRf+>
Unit
V (volts)
RST Value
0
Example
VOLT:TRIG 15 VOLTAGE:LEVEL:TRIGGERED 15
Query syntax
[SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude]?
Returns
<NR3>
Related Command
VOLT VOLT:PROT

Table of Contents

Other manuals for ITech IT6400 Series

Related product manuals