Scope commands
Copyright © Itech Electronic Co., Ltd. 99
Arguments
UP|DOWN|UPDown
RST Value
UP
Example
SCOPe:TRIGer:SLOPe UP
Query syntax
SCOPe:TRIGer:SLOPe?
Returns
UP|DOWN|UPDown
SCOPe:TRIGer:DELay
This command sets the trigger delay time of oscilloscope function.
Command syntax
SCOPe:TRIGer:DELay< NRF >
Arguments
-2000-2000
Unit
ms
Example
SCOPe:TRIGer:DELay 5
Query syntax
SCOPe:TRIGer:DELay?
Returns
<NRF>
SCOPe:DATA?
This command sets to obtain the current wave of oscilloscope. Reply 900 float
data at one time. The middle shall be separated by a comma.