Trigger commands
Copyright © Itech Electronic Co., Ltd. 79
Arguments
0 to MAX
Unit
V (volts)
RSTValue
0
Example
TRIG:SEQ2:LEV:DVM 5
Query syntax
TRIGger:SEQuence2:LEVel:DVM?
TRIGger:ACQuire:LEVel:DVM?
Returns
<NR3>
Related Command
TRIG:SEQ2:HYST:DVM
TRIGger:SEQuence2:LEVel:VOLTage
TRIGger:ACQuire:LEVel:VOLTage
This command sets the trigger level for internally triggered voltage
measurements. A positive voltage trigger occurs when the voltage level
changes from a value less than the lower hysteresis band limit to a value
greater than the upper hysteresis band limit. Similarly, a negative voltage
trigger occurs when the voltage level changes from a value greater than the
upper hysteresis band limit to a value less than the lower hysteresis band limit.
Command syntax
TRIGger:SEQuence2:LEVel:VOLTage<NRf+>
TRIGger:ACQuire:LEVel:VOLTage<NRf+>
Arguments
0 to MAX