Measurement Commands
Copyright © Itech Electronic Co., Ltd. 50
Arguments
50 through 600
RST Value
600
Example
SENS:SWE:POIN 600
Query syntax
SENSe:SWEep:POINts?
Returns
<NR3>
Related Command
SENS:SWE:TINT SENS:SWE:OFFS MEAS:ARR
SENSe:SWEep:TINTerval
This command defines the time period between samples. The value that you
enter for the time interval will be rounded to the nearest 33.33 microsecond
increment.
Command syntax
SENSe:SWEep:TINTerval<NRf+>
Arguments
33.33 microseconds through 1 seconds
RST Value
33.33 microseconds
Example
SENS:SWE:TINT 66.66E-6
Query syntax
SENSe:SWEep:TINTerval?
Returns
<NR3>