Output command
Copyright © Itech Electronic Co., Ltd. 54
Chapter7 Output command
OUTPut Subsystem, source output function, OVP, OCP, voltage value, current
value upper limit setting, source output speed setting, source isolation output
control. Instrument command, Output command, Source command.
OUTPut[:STATe]
This command enables or disables the instrument output. Parameters include 1,
0, ON and OFF.
Command syntax
OUTPut[:STATe]<bool>
Arguments
0|1|ON|OFF
Example
OUTP 1 OUTP OFF
Query syntax
OUTPut[:STATe]?
Returns
0|1
OUTPut:OFF:MODE
This command sets the output off mode.
Command syntax
OUTPut:OFF:MODE <type>
Arguments
HIMPedance | NORMal | ZERo | OFF
Example
OUTP:OFF:MODE NORMal