Output command
Copyright © Itech Electronic Co., Ltd. 66
[SOURce:]CURRent:LIMit
This command sets the upper limit of source current.
Model
The setting range of source current upper limit
IT6411
0.002A ~ 5.05A
IT6411S
0.00005A ~ 0.1A
IT6431
0.01A ~ 10.05A
IT6432
0.002A ~ 5.05A
IT6433
0.002A ~ 2.55A
IT6432S
10uA ~ 21mA
Command syntax
CURRent:LIMit < NRf >
Arguments
< NRf >
Unit
A(Amps)
Example
CURR:LIM 0.05
Query syntax
CURRent:LIMit?
Returns
< NRf >
[SOURce:]RESistance[:LEVel][:IMMediate][:AMPLitude
]
This command sets the source internal resistance.
Model
The setting range of the source internal resistance.
IT6411
0-1
IT6411S
0-20
IT6431
0-1
IT6432
0-1
IT6433
0-1

Table of Contents