Scope commands
Copyright © Itech Electronic Co., Ltd. 94
Returns
<NRF>
SCOPe:CURRent:BASE
This command sets the current base address of oscilloscope function.
Model
Current base address setting range
IT6411
-5A ~ +5A
IT6411S
-0.1A ~ +0.1A
IT6431
-10A ~ +10A
IT6432
-5A ~ +5A
IT6433
-2.5A ~ +2.5A
IT6432S
-21mA ~ +21mA
Command syntax
SCOPe:CURRent:BASE < NRF >
Arguments
< NRF >
RST Value
0
Example
SCOP:CURR:BASE 0
Query syntax
SCOPe:CURR:BASE?
Returns
<NRF>
SCOPe:DVM:BASE
This command sets the digital voltmeter base address of oscilloscope function.
Model
DVM base address setting range
IT6411
-20V~ +20V
IT6411S
-20V~ +20V
IT6431
-20V~ +20V
IT6432
-30V~ +30V