IEEE-488 Commands
Copyright © Itech Electronic Co., Ltd. 13
Example
*ESE 129
Query syntax
*ESE?
Returns
<NR1>
Related Command
*ESR? *PSC *STB?
*ESR?
This query reads the Standard Event Status Event register. Reading the
register clears it. The bit configuration of this register is the same as the
Standard Event Status Enable register (see *ESE). See chapter
“Programming the Status Registers” for a detailed explanation of this
register.
Query syntax
*ESR?
Arguments
None
Returns
<NR1> (register value)
Related Command
*CLS *ESE *ESE? *OPC
*IDN?
This query requests the power supply to identify itself. It returns the data in four
fields separated by commas.
Query syntax
*IDN?
Arguments
None