Trigger commands
Copyright © Itech Electronic Co., Ltd. 77
Returns
< CRD >
TRIGger:SEQuence2
TRIGger:ACQuire
These commands generate a BUS trigger for the measurement trigger system.
When the measurement trigger system is enabled, the measurement trigger
causes the dc source to measure either the voltage or current on the main
output or the DVM inputs and store the results in a buffer. The
SENSe:FUNCtion command selects the signal that will be measured.
Command syntax
TRIGger:SEQuence2[:IMMediate]
TRIGger:ACQuire[:IMMediate]
Arguments
None
Example
TRIG:SEQ2
TRIG:ACQ
Related Command
TRIG:SOUR TRIG:SEQ2:DEF TRIG:SEQ2:COUN
TRIGger:SEQuence2:LEVel:CURRent
TRIGger:ACQuire:LEVel:CURRent
This command sets the trigger level for internally triggered current
measurements. A positive current trigger occurs when the current level
changes from a value less than the lower hysteresis band limit to a value
greater than the upper hysteresis band limit. Similarly, a negative current trigger
occurs when the current level changes from a value greater than the upper
hysteresis band limit to a value less than the lower hysteresis band limit.
Command syntax
TRIGger:SEQuence2:LEVel:CURRent<NRf+>

Table of Contents

Other manuals for ITech IT6400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6400 Series and is the answer not in the manual?

ITech IT6400 Series Specifications

General IconGeneral
BrandITech
ModelIT6400 Series
CategoryPower Supply
LanguageEnglish

Related product manuals