Status commands
Copyright © Itech Electronic Co., Ltd. 24
mainframe.
Command syntax
STATus:OPERation:ENABle <NR1>
Arguments
0 to 65535
Default Value
0
Example
STAT:OPER:ENAB 32 STAT:OPER:ENAB 1
Query syntax
STATus:OPERation:ENABle?
Returns
<NR1> (register value)
Related Command
STAT:OPER?
STATus:OPERation:CONDition?
This query returns the value of the Operation Condition register. That is a
read-only register that holds the real-time (unlatched) operational status of the
power supply. This command is not channel specific, it applies to the entire
mainframe.
Query syntax
STATus:OPERation:CONDition?
Arguments
None
Example
STAT:OPER:COND?
Returns
<NR1> (register value)