EasyManua.ls Logo

ITech IT6400 Series - [Source:]Voltage:limit:state; [Source:]Voltage:limit

ITech IT6400 Series
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Output command
Copyright © Itech Electronic Co., Ltd. 71
[SOURce:]VOLTage:LIMit:STATe
This command sets the source OVP state. Parameters include 1, 0, ON and
OFF, Parameters include 0|1|ON|OFF.
Command syntax
[SOURce:]VOLTage:LIMit:STATe <bool>
Arguments
0|1|ON|OFF
Example
VOLT:LIM:STAT 1
Query syntax
[SOURce:]VOLTage:LIMit:STATe?
Returns
0|1
[SOURce:]VOLTage:LIMit
This command sets the upper limit of source voltage.
Model
The setting range of source voltage upper limit
IT6411
0~ 15.1V
IT6411S
0 ~ 15.1V
IT6431
0 ~ 15.1V
IT6432
0 ~ 30.1V
IT6433
0 ~ 60.1V
IT6432S
0 ~ 30.1V
Command syntax
VOLTage:LIMit < NRf >
Arguments
< NRf >
Unit
V(Volts)

Table of Contents

Other manuals for ITech IT6400 Series

Related product manuals