Output command
Copyright © Itech Electronic Co., Ltd. 71
[SOURce:]VOLTage:LIMit:STATe
This command sets the source OVP state. Parameters include 1, 0, ON and
OFF, Parameters include 0|1|ON|OFF.
Command syntax
[SOURce:]VOLTage:LIMit:STATe <bool>
Arguments
0|1|ON|OFF
Example
VOLT:LIM:STAT 1
Query syntax
[SOURce:]VOLTage:LIMit:STATe?
Returns
0|1
[SOURce:]VOLTage:LIMit
This command sets the upper limit of source voltage.
Model
The setting range of source voltage upper limit
IT6411
0~ 15.1V
IT6411S
0 ~ 15.1V
IT6431
0 ~ 15.1V
IT6432
0 ~ 30.1V
IT6433
0 ~ 60.1V
IT6432S
0 ~ 30.1V
Command syntax
VOLTage:LIMit < NRf >
Arguments
< NRf >
Unit
V(Volts)