Trigger commands
Copyright © Itech Electronic Co., Ltd. 75
causes the specified triggering action to occur. If the trigger subsystem is not
enabled, all triggers are ignored.
Command syntax
INITiate[:IMMediate]:SEQuence
INITiate[:IMMediate]:NAME<name>
Arguments
TRANsient | ACQuire (for INIT:NAME )
Example
INIT:SEQ
INIT:NAME TRAN
Related Command
ABOR INIT:CONT TRIG TRIG:SEQ:DEF *TRG
INITiate:CONTinuous:SEQuence1
1 or ON continuously initiates the output trigger system.
0 or OFF turns off continuous triggering. In this state, the output trigger system
must be initiated for each trigger using INITiate:SEQuence.
Command syntax
INITiate:CONTinuous:SEQuence1 <bool>
Arguments
0 | 1 | OFF | ON
Example
INIT:CONT:SEQ1 ON
Related Command
ABOR INIT TRIG TRIG:SEQ:DEF *TRG
TRIGger
This command generates a BUS trigger for the output transient trigger system.
If the transient trigger system is enabled, the trigger will then:
1. Initiate a pending level change as specified by CURRent:TRIGger or
VOLTage:TRIGger.

Table of Contents

Other manuals for ITech IT6400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6400 Series and is the answer not in the manual?

ITech IT6400 Series Specifications

General IconGeneral
BrandITech
ModelIT6400 Series
CategoryPower Supply
LanguageEnglish

Related product manuals