Output command
Copyright © Itech Electronic Co., Ltd. 63
Query syntax
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]?
Returns
< NR3 >
[SOURce:]CURRent:PROTection:STATe
This command sets the source OCP state of all channels. If source current is in
CC state and OCP is on, the output will be switched off and the Questionable
Condition state register OC bit will be set as 1. This CC value is set by
[SOURce: ]CURRent command. The OCP state can be cleared by
OUTPut:PROTection:CLEar. Parameters include 1, 0, ON and OFF. When
current exceeds the OCP value, the power supply will be switched off.
Command syntax
[SOURce:]CURRent:PROTection:STATe <bool>
Arguments
0|1|ON|OFF
Example
CURR:PROT:STAT 1 CURR2:PROT:STAT OFF
Query syntax
[SOURce:]CURRent:PROTection:STATe?
Returns
0|1
Related Command
OUTP:PROT:CLE *RST
[SOURce:]CURRent:TRIGgered
This command sets a preset current value for source. This preset value will be
promptly transferred to output if a trigger is generated. To generate trigger, the
trigger subsystem must be initialized (in trigger subsystem, INITiate command
is used for initialize trigger).
Command syntax
[SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude] <NRf+>