Trigger commands
Copyright © Itech Electronic Co., Ltd. 74
Chapter8 Trigger commands
Trigger commands consist of trigger and initiate commands. They are used to
generate output transients and measurement triggers.
Initiate initialize the trigger system.
Trigger control the remote triggering of the dc source. Trigger commands (and
Initiate commands) are referenced either by name or by number. The
correspondence between names and numbers is:
Sequence Number Sequence Name Description
1 (the default) TRANsient Output transient trigger sequence
2 ACQuire Measurement acquire trigger sequence
ABORt
This command cancels any trigger actions presently in process. Pending trigger
levels are reset to their corresponding immediate values. ABORt also resets the
WTG bit in the Operation Condition Status register (see chapter 7 about
programming the status registers). If INITiate:CONTinuous ON has been
programmed, the trigger subsystem initiates itself immediately after ABORt,
thereby setting WTG.
Command syntax
ABORt
Arguments
None
Example
ABOR
Related Command
INIT *RST *TRG TRIG
INITiate:SEQuence
INITiate:NAME
INITiate commands control the enabling of both output and measurement
triggers. When a trigger is enabled, an event on a selected trigger source

Table of Contents

Other manuals for ITech IT6400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6400 Series and is the answer not in the manual?

ITech IT6400 Series Specifications

General IconGeneral
BrandITech
ModelIT6400 Series
CategoryPower Supply
LanguageEnglish

Related product manuals