EasyManuals Logo

ITech IT6400 Series Programming Guide

ITech IT6400 Series
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #120 background imageLoading...
Page #120 background image
Battery commands
Copyright © Itech Electronic Co., Ltd. 108
IT6411
0 ~ 15.1V
IT6411S
0 ~ 15.1V
IT6431
0 ~ 15.1V
IT6432
0 ~ 30.1V
IT6433
0 ~ 60.1V
IT6432S
0 ~ 30.1V
Command syntax
BATTery:VOLTage < NRf >
Arguments
< NRf >
Unit
V
Example
BATTery:VOLTage 10
Query syntax
BATTery:VOLTage?
Returns
<NRF>
BATTery:CURRent <NRf>
This command sets the charge or discharge current value of BATTERY.
Model
The setting range of Charge or discharge current value
IT6411
0.002A ~ 5.05A
IT6411S
0.00005A ~ 0.1A
IT6431
0.01A ~ 10.05A
IT6432
0.002A ~ 5.05A
IT6433
0.002A ~ 2.55A
IT6432S
10uA ~ 21mA
Command syntax
BATTery:CURRent< NRf >

Table of Contents

Other manuals for ITech IT6400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6400 Series and is the answer not in the manual?

ITech IT6400 Series Specifications

General IconGeneral
BrandITech
ModelIT6400 Series
CategoryPower Supply
LanguageEnglish

Related product manuals