List commands
Copyright © Itech Electronic Co., Ltd. 112
Example
LIST:POINt 1
Query syntax
LIST:POINt?
Returns
<NR1>
LIST:PARamneter <NRf>,<NRf>,<NRf>,<NRf>
This command sets 4 parameters of the current point of the current group, i.e.,
voltage, current, internal resistance and duration.
Command syntax
LIST:PARameter< NRf >
Arguments
VOLT,CURR,RES,DWELL
Example
LIST:PARameter 15.0,3.0,0,0.1
Query syntax
LIST:PARameter?
Returns
<NRf>,<NRf>,<NRf>,<NRf>
LIST:GROup:SELect <NRf>
This command sets which group is in enabled status.
Command syntax
LIST:GROup:SELect < NRf >
Arguments
0-19
Example
LIST:GROup:SELect 5 (Select to enable the fifth group)