Battery commands
Copyright © Itech Electronic Co., Ltd. 105
BATTery:TIME:SHUT <NRf>
This command sets the operation time shut-off value of BATTERY.
Command syntax
BATTery:TIME:SHUT< NRf >
Arguments
0-999999
Unit
s
Example
BATTery:TIME:SHUT 9999
Query syntax
BATTery:TIME:SHUT?
Returns
<NR1>
BATTery:STARt
This command sets to start operation of BATTERY.
Command syntax
BATTery:STARt
Arguments
NONE
Example
BATT:STAR
BATT2:STAR
BATTery:STOP
This command sets to stop operation of BATTERY.
Command syntax
BATTery:STOP