4-229
Line 10 Selects semi-synchronous Trigger Link protocol, and then queries the selected pro-
tocol.
Line 20 Addresses the Model 2001 to talk.
Line 30 Displays the Trigger Link protocol (SSYN).
:DIRection <name>
:ARM[:SEQuence[1]][:LAYer[1]]:TCONfigure:DIRection <name> Control arm Source Bypass
:ARM[:SEQuence[1]]:LAYer2:TCONfigure:DIRection <name> Control scan Source Bypass
:TRIGger[:SEQuence[1]]:TCONfigure:DIRection <name> Control measure Source By-
pass
Parameters <name> = SOURce Enable Source Bypass
= ACCeptor Disable Source Bypass
Formats :arm:tcon:dir <name>
:arm:lay2:tcon:dir <name>
:trig:tcon:dir <name>
Defaults Power-up Saved power-on setup
*RST ACCeptor (all layers)
:SYSTem:PRESet ACCeptor (all layers)
Query :DIRection? Query Source Bypass state
Short-form formats: :arm:tcon:dir?
:arm:lay2:tcon:dir?
:trig:tcon:dir?
Response message: SOUR or ACC
Description When a Source Bypass is enabled and the External or Trigger Link arm control source is select-
ed, operation will loop around the appropriate control source on the initial pass through that lay-
er. Note that the Source Bypass for the scan and measure layers also loops around the Delay.
If programmed for another pass through the specified layer (count >1), the bypass loop will not
be in effect even though it will still be enabled. The bypass loop will be in effect if operation first
goes back into the previous layer (or idle).
Enabling the Source Bypass for the arm and scan layers also enables their Output Triggers.
When operation leaves the arm or scan layer, the appropriate output trigger pulse will occur. If
the Trigger Link (TLINk) control source is selected, the output trigger will be available on the
programmed Trigger Link output line. For all other control source selections, the output trigger
pulse will be available at the METER COMPLETE Output connector. The Output Trigger in
these two layers is disabled when the Source Bypass is disabled.
The Output Trigger in the measure layer is always enabled and occurs after the Device Action.
With ACCeptor selected, the bypass is disabled, This simply means that operation will not pro-
ceed through the specified layer until the appropriate event occurs.

Table of Contents

Other manuals for Keithley 2001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2001 and is the answer not in the manual?

Keithley 2001 Specifications

General IconGeneral
BrandKeithley
Model2001
CategoryMultimeter
LanguageEnglish

Related product manuals