SCPI Conformance Information
J-7
:TRIGger[:SEQuence[1]]
:IMMediate
:COUNt <n>
:COUNt?
:DELay <n>
:DELay?
:SOURce <name>
:SOURce?
:TIMer <n>
:TIMer?
:SIGNal
:UNIT
:TEMPerature <name>
:TEMPerate?
Path to program trigger layer:
Loop around control source.
Program measure count (1 to 99999, or INF).
Query measure count.
Program delay (0 to 999999.999 sec).
Query delay.
Select control source: HOLD, IMMediate, TIMer, MANual, BUS, TLINk, EXTernal.
Query control source.
Set timer interval (0 to 999999.999 sec).
Request the programmed timer interval.
Loop around control source.
Select temperature measurement units: C, CEL, F, FAR, K.
Query temperature units.
Table J-2
Syntax of non-SCPI commands implemented by Model 2001
Command Description
:CALCulate[1]
:KMATh
:MMFactor <NRf>
:MMFactor?
:MBFactor <NRf>
:MBFactor?
:PERCent <NRf>
:PERCent?
:CALCulate3
:PASS
:SOURce <NRf>
:BSTRobe
:STATe <b>
:STATe?
:CALibration
:PROTected
:LOCK
:SWITch?
:SAVE
:DATA?
:DATE “<string>”
:DATE?
:NDUE “<string>”
:NDUE?
:LLEVel
:SWITch?
Subsystem to control CALC 1:
Path to configure math calculations:
Specify “m” for mX+b (-9.99e35 to +9.99e20).
Query “m” factor.
Specify “b” for mX+b (-9.99e35 to +9.99e30).
Query “b” factor.
Set Percent value (-2.0e9 to +2.0e9).
Query PERCENT.
Subsystem to control CALC3 (limit tests):
Path to define “pass” digital output pattern.
Specify digital output (0 to 15).
Path to control limit binning strobe:
Enable (1 or ON) or disable (0 or OFF) strobe.
Query state of binning strobe.
Calibration root command.
All commands in this subsystem are protected by the CAL switch.
Lock out calibration (opposite of enabling cal with CAL switch).
Request comprehensive CAL switch state. (0 = locked; 1 = unlocked)
Save cal constants to EEPROM.
Download cal constants from 2001.
Send cal date to 2001.
Request cal date from 2001.
Send next due cal date to 2001.
Request next due cal date from 2001.
Low-level calibration subsystem.
Request low-level CAL switch state. (0 = locked; 1 = unlocked)
Table J-1 (cont.)
Syntax of SCPI confirmed commands implemented by Model 2001
Command Description

Table of Contents

Other manuals for Keithley 2001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2001 and is the answer not in the manual?

Keithley 2001 Specifications

General IconGeneral
BrandKeithley
Model2001
CategoryMultimeter
LanguageEnglish

Related product manuals