Front Panel Operation
3-45
Figure 3-18
3-wire RTD temperature measurements
NEXT
DISPLAY
PREV
POWER
DCV ACV DCI ACI 2 4
FREQ TEMP
REL TRIG STORE RECALL
INFO LOCAL CHAN SCAN CONFIG MENU EXIT ENTER
RANGE
AUTO
FILTER MATH
RANGE
2001 MULTIMETER
SENSE
4 WIRE
HI
INPUT
LO
INPUTS
CAL
500V
PEAK
F
R
FRONT/REAR
2A 250V
AMPS
350V
PEAK
1100V
PEAK
Model 2001
Platinum
RTD
Input HI
Input LO
Sense 4-wire LO
A. Connections to Banana Jacks
WARNING : To avoid a shock hazard and possible instrument damage,
do not use the Model 8680 RTD Probe Adapter to measure voltages
exceeding 30V RMS, 42.4V peak.
NEXT
DISPLAY
PREV
POWER
DCV ACV DCI ACI 2 4
FREQ TEMP
REL TRIG STORE RECALL
INFO LOCAL CHAN SCAN CONFIG MENU EXIT ENTER
RANGE
AUTO
FILTER MATH
RANGE
2001 MULTIMETER
SENSE
4 WIRE
HI
INPUT
LO
INPUTS
CAL
500V
PEAK
F
R
FRONT/REAR
2A 250V
AMPS
350V
PEAK
1100V
PEAK
Model 2001
Platinum
RTD
Input HI
Input LO
Sense 4-wire LO
B. Connections to Terminal Block
8680
RTD PROBE ADAPTER
RANGE: -220°C TO 630°C
-360°F TO 1100°F
MADE
IN
U.S.A.
42V
PEAK
RTD
HI
SENSE
HI LO
SENSE
LO
Input HI
Sense 4-wire LO
Input LO
1234
Short
Short
+000.00 °C
4W-RTD type : PT385
Short
+000.00 °C
4W-RTD type : PT385
Figure 3-19
2-wire RTD temperature measurements
NEXT
DISPLAY
PREV
POWER
DCV ACV DCI ACI 2 4
FREQ TEMP
REL TRIG STORE RECALL
INFO LOCAL CHAN SCAN CONFIG MENU EXIT ENTER
RANGE
AUTO
FILTER MATH
RANGE
2001 MULTIMETER
SENSE
4 WIRE
HI
INPUT
LO
INPUTS
CAL
500V
PEAK
F
R
FRONT/REAR
2A 250V
AMPS
350V
PEAK
1100V
PEAK
Model 2001
Platinum
RTD
Input HI
Input LO
A. Connections to Banana Jacks
+000.00 °C
RTD type : PT385
WARNING : To avoid a shock hazard and possible instrument damage,
do not use the Model 8680 RTD Probe Adapter to measure voltages
exceeding 30V RMS, 42.4V peak.
NEXT
DISPLAY
PREV
POWER
DCV ACV DCI ACI 2 4
FREQ TEMP
REL TRIG STORE RECALL
INFO LOCAL CHAN SCAN CONFIG MENU EXIT ENTER
RANGE
AUTO
FILTER MATH
RANGE
2001 MULTIMETER
SENSE
4 WIRE
HI
INPUT
LO
INPUTS
CAL
500V
PEAK
F
R
FRONT/REAR
2A 250V
AMPS
350V
PEAK
1100V
PEAK
Model 2001
Platinum
RTD
Input HI
Input LO
B. Connections to Terminal Block
8680
RTD PROBE ADAPTER
RANGE: -220°C TO 630°C
-360°F TO 1100°F
MADE
IN
U.S.A.
42V
PEAK
RTD
HI
SENSE
HI LO
SENSE
LO
Input HI Input LO
1234
+000.00 °C
RTD type : PT385

Table of Contents

Other manuals for Keithley 2001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2001 and is the answer not in the manual?

Keithley 2001 Specifications

General IconGeneral
BrandKeithley
Model2001
CategoryMultimeter
LanguageEnglish

Related product manuals