SCPI Conformance Information
J-6
:STATus
:PRESet
:QUEue
[:NEXT]?
:ENABle <list>
:ENABle?
:SYSTem
:PRESet
:VERSion?
:ERRor?
:KEY <NRf>
:KEY?
:TRACe|:DATA
:FREE? [BUFFER,]
:POINts [BUFFER,] <n>
:AUTO [BUFFER,] <b>
:AUTO? [BUFFER,]
:POINts? [BUFFER,]
:FEED [BUFFER,] <name>
:CONTrol [BUFFER,] <name>
:CONTrol? [BUFFER,]
:FEED? [BUFFER,]
:DATA? [BUFFER,]
:INITiate
[:IMMediate]
:CONTinuous <b>
:CONTinuous?
:ABORt
:ARM[:SEQuence[1]]
[:LAYer[1]]
:IMMediate
:COUNt <n>
:COUNt?
:SOURce <name>
:SOURce?
:SIGNal
:LAYer2
:IMMediate
:COUNt <n>
:COUNt?
:DELay <n>
:DELay?
:SOURce <name>
:SOURce?
:TIMer <n>
:TIMer?
:SIGNal
Return status registers to default states.
Path to access error queue:
Read the most recent error message.
Specify error and status messages for queue.
Read the enabled messages.
Return to :SYST:PRES defaults.
Query rev level of SCPI standard.
Query (rear) Error Queue.
Simulate key-press (1 to 31; see Figure 4-40).
Query the last “pressed” key.
Use :TRACe or :DATA as root command.
Query bytes available and bytes in use.
Specify size of buffer.
Enable (1 or ON) or disable auto buffer sizing.
Query state of auto buffer sizing.
Query buffer size.
Select source of readings: SENSe[1], CALCulate[1], NONE.
Select buffer control mode: NEVer, NEXT, ALWays, PRETrigger.
Query buffer control mode.
Query source of readings for buffer.
Read all readings in the buffer.
Subsystem command path:
Initiate one trigger cycle.
Enable (1 or ON) or disable (0 or OFF) continuous initiation of trigger system.
Query continuous initiation.
Reset trigger system.
Subsystem command path to configure arm layers:
Path to program arm layer 1:
Loop around control source.
Program arm count (1 to 99999, or INF).
Query arm count.
Select control source: HOLD, IMMediate, MANual, BUS, TLINk, EXTernal.
Query control source.
Loop around control source.
Path to program arm layer 2.
Loop around control source.
Program scan count (1 to 99999, or INF).
Query scan count.
Program delay (0 to 999999.999 sec).
Query delay.
Select control source: HOLD, IMMediate, TIMer, MANual, BUS, TLINk, EXTernal.
Query control source.
Set timer interval (0 to 999999.999 sec).
Query timer.
Loop around control source.
Table J-1 (cont.)
Syntax of SCPI confirmed commands implemented by Model 2001
Command Description