SCPI Conformance Information
J-3
:ROUTe
:CLOSe <list>
:STATe?
:CLOSe? <list>
:OPEN <list>
:OPEN:ALL
:OPEN <list>
:SCAN
[:INTernal] <list>
[:INTernal]?
[:SENSe[1]]
:FUNCtion <name>
:FUNCtion?
:DATA?
:CURRent:AC
:APERture <n>
:APERture?
:NPLCycles <n>
:NPLCycles?
:RANGe
[:UPPer] <n>
[:UPPer]?
:AUTO <b>
:AUTO ONCE
:AUTO?
:REFerence <n>
:STATe <b>
:STATe?
:REFerence?
:CURRent:DC
:APERture <n>
:APERture?
:NPLCycles <n>
:NPLCycles?
:RANGe
[:UPPer] <n>
[:UPPer]?
:AUTO <b>
:AUTO ONCE
:AUTO?
:REFerence <n>
:STATe <b>
:STATe?
:REFerence?
:VOLTage:AC
:APERture <n>
:APERture?
:NPLCycles <n>
:NPLCycles?
Path and command to close specified channel:
Query closed channel.
Query specified channels (1 = closed, 0 = open).
Open specified channel or all channels.
Open all channels.
Query specified channels (1 = open, 0 = closed).
Command path to configure and control scan operations:
Specify an internal scan list (2 to 10 channels).
Query the internal scan list.
Select measurement function: ‘VOLTage:AC’, ‘VOLTage:DC’, RESistance’,‘CURRent:AC’,
‘CURRent:DC’, ‘FREQuency’, TEMPerature’
Query function.
Query latest reading.
Path to configure AC current:
Specify integration rate in seconds (166.67e-6 to 200e-3).
Query aperture (integration rate).
Specify integration rate (number of line cycles; 0.01 to 10).
Query line cycle integration rate.
Path to configure measurement range:
Select range (0 to +2.1).
Query range.
Enable (1 or ON) or disable (0 or OFF) auto range.
Set range based on present input signal.
Query auto range.
Specify reference (REL) value (-2.1 to +2.1).
Enable (1 or ON) or disable (0 or OFF) REL.
Query state of REL (0 or 1).
Query reference (REL) value.
Path to configure DC current.
Specify integration rate in seconds (166.67e-6 to 200e-3).
Query aperture (integration rate).
Specify integration rate (number of line cycles; 0.01 to 10).
Query line cycle integration rate.
Path to configure measurement range:
Select range (0 to +2.1).
Query range.
Enable (1 or ON) or disable (0 or OFF) auto range.
Set range based on present input signal.
Query auto range.
Specify reference (REL) value (-2.1 to +2.1).
Enable (1 or ON) or disable (0 or OFF) REL.
Query state of REL (0 or 1).
Query reference (REL) value.
Path to configure AC voltage.
Specify integration rate in seconds (166.67e-6 to 200e-3).
Query aperture (integration rate).
Specify integration rate (number of line cycles; 0.01 to 10).
Query line cycle integration rate.
Table J-1 (cont.)
Syntax of SCPI confirmed commands implemented by Model 2001
Command Description

Table of Contents

Other manuals for Keithley 2001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2001 and is the answer not in the manual?

Keithley 2001 Specifications

General IconGeneral
BrandKeithley
Model2001
CategoryMultimeter
LanguageEnglish

Related product manuals