SCPI Conformance Information
J-3
:ROUTe
:CLOSe <list>
:STATe?
:CLOSe? <list>
:OPEN <list>
:OPEN:ALL
:OPEN <list>
:SCAN
[:INTernal] <list>
[:INTernal]?
[:SENSe[1]]
:FUNCtion <name>
:FUNCtion?
:DATA?
:CURRent:AC
:APERture <n>
:APERture?
:NPLCycles <n>
:NPLCycles?
:RANGe
[:UPPer] <n>
[:UPPer]?
:AUTO <b>
:AUTO ONCE
:AUTO?
:REFerence <n>
:STATe <b>
:STATe?
:REFerence?
:CURRent:DC
:APERture <n>
:APERture?
:NPLCycles <n>
:NPLCycles?
:RANGe
[:UPPer] <n>
[:UPPer]?
:AUTO <b>
:AUTO ONCE
:AUTO?
:REFerence <n>
:STATe <b>
:STATe?
:REFerence?
:VOLTage:AC
:APERture <n>
:APERture?
:NPLCycles <n>
:NPLCycles?
Path and command to close specified channel:
Query closed channel.
Query specified channels (1 = closed, 0 = open).
Open specified channel or all channels.
Open all channels.
Query specified channels (1 = open, 0 = closed).
Command path to configure and control scan operations:
Specify an internal scan list (2 to 10 channels).
Query the internal scan list.
Select measurement function: ‘VOLTage:AC’, ‘VOLTage:DC’, RESistance’,‘CURRent:AC’,
‘CURRent:DC’, ‘FREQuency’, TEMPerature’
Query function.
Query latest reading.
Path to configure AC current:
Specify integration rate in seconds (166.67e-6 to 200e-3).
Query aperture (integration rate).
Specify integration rate (number of line cycles; 0.01 to 10).
Query line cycle integration rate.
Path to configure measurement range:
Select range (0 to +2.1).
Query range.
Enable (1 or ON) or disable (0 or OFF) auto range.
Set range based on present input signal.
Query auto range.
Specify reference (REL) value (-2.1 to +2.1).
Enable (1 or ON) or disable (0 or OFF) REL.
Query state of REL (0 or 1).
Query reference (REL) value.
Path to configure DC current.
Specify integration rate in seconds (166.67e-6 to 200e-3).
Query aperture (integration rate).
Specify integration rate (number of line cycles; 0.01 to 10).
Query line cycle integration rate.
Path to configure measurement range:
Select range (0 to +2.1).
Query range.
Enable (1 or ON) or disable (0 or OFF) auto range.
Set range based on present input signal.
Query auto range.
Specify reference (REL) value (-2.1 to +2.1).
Enable (1 or ON) or disable (0 or OFF) REL.
Query state of REL (0 or 1).
Query reference (REL) value.
Path to configure AC voltage.
Specify integration rate in seconds (166.67e-6 to 200e-3).
Query aperture (integration rate).
Specify integration rate (number of line cycles; 0.01 to 10).
Query line cycle integration rate.
Table J-1 (cont.)
Syntax of SCPI confirmed commands implemented by Model 2001
Command Description

Table of Contents

Other manuals for Keithley 2001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2001 and is the answer not in the manual?

Keithley 2001 Specifications

General IconGeneral
Model2001
CategoryMultimeter
ManufacturerKeithley
TypeDigital Multimeter
Digits of Resolution7.5
DC Voltage Range100 mV to 1000 V
AC Voltage Range100 mV to 750 V
Frequency Range3 Hz to 500 kHz
ConnectivityGPIB, RS-232
DisplayVFD
Resistance Accuracy0.008% + 2.0 mΩ
Frequency Accuracy±0.01%
DC Current Range10 μA to 3 A
AC Current Range10 μA to 3 A
Power Supply100 V to 240 V AC, 45 Hz to 66 Hz