CAUTION:
The power-control button on the device does not turn off the electrical current supplied to the device.
The device also might have more than one connection to dc power. To remove all electrical current
from the device, ensure that all connections to dc power are disconnected at the dc power input
terminals.
Attention:
Read
“Installation Guidelines” on page 57 and “Safety inspection checklist” on page 58 to ensure that you
work safely.
Keep static-sensitive parts in their static-protective packages until installation to prevent exposure to
static electricity. Handle the parts with an electrostatic-discharge wrist strap or other grounding systems.
Place the parts on a static-protective surface.
Procedure
Step 1. If there is a power-supply-unit filler installed, remove it.
Figure 131. Hot-swap power-supply-unit filler removal
a. Pinch the latches to unlock the power-supply-unit filler.
b.
Pull out the filler.
Step 2. Slide the new hot-swap power supply unit into the bay until it snaps into position.
Important:
Depends on the model, the color of release tab might be different.
If the power supply unit is to be replaced by a new one, make sure that the new one has identical
color of the release tab, wattage and efficiency with the old one.