Lenze · I/O system 1000 · Reference Manual · DMS 5.0 EN · 09/2016 · TD17 22
2 Product description
2.4 Digital-I/O EPM-S207, EPM-S310 – time stamp function (example)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Executing the time stamp function for the 1st entry
In order that the outputs can be triggered accordingly, you have to enable them before. In this
example, you enable both outputs with the 1st "running number" (RN).
The 1st time stamp entry (RN = 0x01) is executed and deleted from the FIFO memory.
The diagram indicates the status of the outputs at the "t" time.
[2-3] Time diagram: Execute time stamp function for the 1st entry
Executing the time stamp function for the entries 2 ... 4
The states of the time stamp entries 2 ... 4 (RN = 0x02 ... 0x04) are output successively and deleted
from the FIFO memory.
The diagram indicates the status of the outputs at the "t" time.
[2-4] Time diagram: Execute the time stamp function for the entries 2 ... 4
FIFO Output data Consecutive number (RN) Ticker value
in μs
Input data
1 0b10110000 0x02 12506 RN_LAST: 0x45
RN_NEXT: 0xC2
STS_FIFO: 0x00/0x02
NUM_ETS: 0x04
2 0b11110000 0x03 34518
3 0b00110000 0x04 49526
4 0b01110000 0x05 54529
5 0b00000000 0x00 0
... 0b00000000 0x00 0
31 0b00000000 0x00 0
FIFO Output data Consecutive number (RN) Ticker value
in μs
Input data
1 0b01110000 0x05 54529 RN_LAST: 0x45
RN_NEXT: 0xC5
STS_FIFO: 0x00/0x02
NUM_ETS: 0x01
2 0b00000000 0x00 0
... 0b00000000 0x00 0
31 0b00000000 0x00 0