Address Name / seng range / [default seng] Informaon
0x2949:002
(P337.02)
Torque limit source selecon:
Negave torque limit
source
(Trq. lim. source: Neg. torqlim src)
•
From version 03.00
Selecon of the source for the negave torque limit source.
0 (-) Max torque Negave torque limit source = (-) Max torque 0x6072 (P326.00).
1 Fixed Limit 0.0 % Negave torque limit source = 0.0 %.
2 Analog Input 1 The negave torque limit source is dened as analog signal via the
analog input 1.
4Analog input 1 ^ 205
3 Analog Input 2 The
negave torque limit source is dened as analog signal via the
analog input 2.
4Analog input 2 ^ 209
4 Negave torque limit Negave torque limit source = Negave torque limit 0x60E1.
5 Network target torque The negave torque limit source is dened as process data object via
ne
twork.
Funcon is not supported in this device.
201 Internal value (from version 05.03) Internal values of the manufacturer.
202 Internal value (from version 05.03)
203 Internal value (from version 05.03)
204 Internal value (from version 05.03)
205 Internal value (fr
om version 05.03)
206 Internal value (from version 05.03)
0x60E0 Posive torque limit
0.0 ... [250.0] ... 3276.7 %
•
Fr
om version 02.00
Posive torque limit source for speed control with torque limitaon.
•
100 % = Ra
ted Motor Torque. 40x6076 (P325.00)
0x60E1 Negave torque limit
0.0 ... [250.0] ... 3276.7 %
•
Fr
om version 02.00
Negave torque limit source for speed control with torque limitaon.
•
100 % = Ra
ted Motor Torque 40x6076 (P325.00)