Address Name Default seng Category Data type Factor A M
0x4027:003
(P802.03)
Sequencer segment 2: Time 0.0 s Sequencer U32 10 P -
0x4027:004
(P802.04)
Sequencer segment 2: Digital outputs 0 Sequencer U8 1 P -
0x4027:005
(P802.05)
Sequencer segment 2: Analog outputs 0.00 VDC Sequencer U16 100 P -
0x4027:006
(P802.06)
Sequencer segment 2: PID setpoint 0.00 PID unit Sequencer I16 100 P -
0x4027:007
(P802.07)
Sequencer segment 2: Torque setpoint 100.0 % Sequencer I16 10 P -
0x4027:008 Sequencer segment 2: NetWordOUT2 0 Sequencer U16 1 P -
0x4027:009 Sequencer segment 2: Reserved 0 Sequencer U32 1 P -
0x4028:001
(P803.01)
Sequencer segment 3: Frequency setpoint 0.0 Hz Sequencer I16 10 P -
0x4028:002
(P803.02)
Sequencer segment 3: Acceleraon/deceleraon 5.0 s Sequencer U16 10 P -
0x4028:003
(P803.03)
Sequencer segment 3: Time 0.0 s Sequencer U32 10 P -
0x4028:004
(P803.04)
Sequencer segment 3: Digital outputs 0 Sequencer U8 1 P -
0x4028:005
(P803.05)
Sequencer segment 3: Analog outputs 0.00 VDC Sequencer U16 100 P -
0x4028:006
(P803.06)
Sequencer segment 3: PID setpoint 0.00 PID unit Sequencer I16 100 P -
0x4028:007
(P803.07)
Sequencer segment 3: Torque setpoint 100.0 % Sequencer I16 10 P -
0x4028:008 Sequencer segment 3: NetWordOUT2 0 Sequencer U16 1 P -
0x4028:009 Sequencer segment 3: Reserved 0 Sequencer U32 1 P -
0x4029:001
(P804.01)
Sequencer segment 4: Frequency setpoint 0.0 Hz Sequencer I16 10 P -
0x4029:002
(P804.02)
Sequencer segment 4: Acceleraon/deceleraon 5.0 s Sequencer U16 10 P -
0x4029:003
(P804.03)
Sequencer segment 4: Time 0.0 s Sequencer U32 10 P -
0x4029:004
(P804.04)
Sequencer segment 4: Digital outputs 0 Sequencer U8 1 P -
0x4029:005
(P804.05)
Sequencer segment 4: Analog outputs 0.00 VDC Sequencer U16 100 P -
0x4029:006
(P804.06)
Sequencer segment 4: PID setpoint 0.00 PID unit Sequencer I16 100 P -
0x4029:007
(P804.07)
Sequencer segment 4: Torque setpoint 100.0 % Sequencer I16 10 P -
0x4029:008 Sequencer segment 4: NetWordOUT2 0 Sequencer U16 1 P -
0x4029:009 Sequencer segment 4: Reserved 0 Sequencer U32 1 P -
0x402A:001
(P805.01)
Sequencer segment 5: Frequency setpoint 0.0 Hz Sequencer I16 10 P -
0x402A:002
(P805.02)
Sequencer segment 5: Acceleraon/deceleraon 5.0 s Sequencer U16 10 P -
0x402A:003
(P805.03)
Sequencer segment 5: Time 0.0 s Sequencer U32 10 P -
0x402A:004
(P805.04)
Sequencer segment 5: Digital outputs 0 Sequencer U8 1 P -
0x402A:005
(P805.05)
Sequencer segment 5: Analog outputs 0.00 VDC Sequencer U16 100 P -
0x402A:006
(P805.06)
Sequencer segment 5: PID setpoint 0.00 PID unit Sequencer I16 100 P -
0x402A:007
(P805.07)
Sequencer segment 5: Torque setpoint 100.0 % Sequencer I16 10 P -
0x402A:008 Sequencer segment 5: NetWordOUT2 0 Sequencer U16 1 P -