Gocator Line Profile Sensors: User Manual
Gocator Web Interface 120
2. Expand the Part Detection panel by clicking on the panel header or the button.
3. If necessary, check the Enabled option.
When Surface Generation is set to Continuous, part detection is always enabled.
4. Adjust the settings.
See the part detection parameters above for more information.
Edge Filtering
Part scans sometimes contain noise around the edges of the target. This noise is usually caused by the
sensor’s light being reflected off almost vertical sides, rounded corners, etc. Edge filtering helps reduce
edge noise in order to produce more accurate and repeatable volume and area measurements, as well as
to improve positioning of relative measurement regions. Optionally, the Preserve Interior Feature
setting can be used to limit filtering to the outside edges of the target.
Edge Filtering disabled (scan shows reflection noise)
Edge Filtering enabled (reflection noise eliminated or reduced)