EasyManua.ls Logo

LMI Technologies Gocator Series - Surface Section Intensity

Default Icon
533 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Gocator Line Profile Sensors: User Manual
Protocols 393
Field Type Offset Description
width (W) 32u 12 Number of points per profile array.
xScale 32u 16 X scale (nm).
zScale 32u 20 Z scale (nm).
xOffset 32s 24 X offset (µm).
zOffset 32s 28 Z offset (µm).
source 8u 32
Source
0 Top
1 Bottom
2 Top Left
3 Top Right
sectionId 32u 33 Section Id
exposure 32u 37 Exposure (ns).
poseAngle 32s 41 Z angle of the pose (microdegrees).
poseX 32s 45 X offset of the pose (µm)
poseY 32s 49 Y offset of the pose (µm)
ranges[C][W] 16s 53 Profile ranges.
The pose field can be used to transform the section data into the surface frame of reference,
via a rotation and then a translation.
Surface Section Intensity
Field Type Offset Description
size 32u 0 Count of bytes in message (including this field).
control 16u 4 Bit 15: Last message flag.
Bits 0-14: Message type identifier. For this message, set to 21.
attributesSize 16u 6 Size of attributes, in bytes (min: 37, current: 37).
count (C) 32u 8 Number of profile intensity arrays
width (W) 32u 12 Number of points per profile intensity array
xScale 32u 16 X scale (nm).
xOffset 32s 20 X offset (µm).
source 8u 24
Source
0 Top
1 Bottom
2 Top Left
3 Top Right
sectionId 32u 25 Section Id.
exposure 32u 29 Exposure (ns).

Table of Contents