Gocator Line Profile Sensors: User Manual
Specifications 520
Master 1200/2400
Master 1200 and 2400 network controllers provide sensor power and safety interlock, and broadcast
system-wide synchronization information (i.e., time, encoder count, encoder index, and digital I/O states)
to all devices on a sensor network.
ThePhoenix connectors on Master 400/800/1200/2400 are not compatible with the connectors
on Master 810/2410. For this reason, if you are switching models in your network, you must
rewire the connections to the Master.
Function Pin
+48VDC 1
+48VDC 2
GND (24-48VDC) 3
GND (24-48VDC) 4
Safety Control+ 5
Safety Control 6
Power and Safety (6 pin connector)
The +48VDCpower supply must be isolated from AC ground. This means that AC ground and
DC ground are not connected.
The Safety Control requires a voltage differential of 24 VDC to 48 VDC across the pin to enable
the laser.