Gocator Line Profile Sensors: User Manual
Protocols 407
Register
Address
Name Type Description
998 Frame Index
999 Fame Index Low
Measurement Registers
Measurement results are reported in pairs of values and decisions. Measurement values are 32 bits wide
and decisions are 8 bits wide.
The measurement ID defines the register address of each pair. The register address of the first word can
be calculated as (1000 + 3 * ID). For example, a measurement with ID set to 4 can be read from registers
1012 (high word) and, 1013 (low word), and the decision at 1015.
In Profile mode, the measurement results are updated after each profile is processed.In Surface mode,
the measurement results are updated after each discrete part has been processed.
Register Address Name Type Description
1000 Measurement 0 High 32s Measurement value in µm (0x80000000
if invalid)
1001
Measurement 0 Low
1002 Decision 0 16u Measurement decision. Abit mask,
where:
Bit 0:
1 - Pass
0 - Fail
Bits 1-7:
0 - Measurement value OK
1 - Invalid value
2 - Invalid anchor
1003 Measurement 1 High
1004
Measurement 1 Low
1005 Decision 1
1006 Measurement 2 High
1007
Measurement 2 Low
1008 Decision 2
... ... ... ...
1057 Measurement 19 High
1058
Measurement 19 Low
1059 Decision 19