Gocator Web Interface 157
To add and configure a tool:
1. Go to the Scan page by clicking on the Scan icon.
2. Choose Profile or Surface mode in the Scan Mode panel.
If one of these modes is not selected, tools will not be available in the Measure panel.
3. Go to the Measure page by clicking on the Measure icon.
4. In the Tools panel, select the tool you want to add from the drop-down list of tools.
5. Click on the Add button in the Tools panel.
The tool and its available measurements are added to the tool list. The tool parameters are listed in the
area below the tool list.
6. (Optional) If you are running a dual-sensor system, choose the sensor that will provide data to the
measurement tool in Source.
For more information on sources, see Source below.
7. (Optional) If the measurement is a profile measurement running on a section, and you have created
more than one section, choose the section that will provide data to the measurement in Stream.
For more information on streams, see Streams (Sections) on the next page.
8. Select a measurement at the bottom of the tool panel.
9. Set any tool- or measurement-specific settings.
For tool- and measurement-specific settings, see the topics for the individual profile or surface tools.
10. Set the Min and Max decision values.
For more information on decisions, see Decisions on page 159.
11. (Optional) Set one or more filters.
For more information on filters, see Filters on page 161.
12. (Optional) Set up anchoring.
For more information on anchoring, see Measurement Anchoring on page 162.
If the drop-down list contains only the Distance measurement, the sensor is not equipped with
profile tools. The Distance measurement is provided in all sensors to demonstrate the
measurement capability.
Source
For dual-sensor systems, you must specify a profile source for measurement tools. The source
determines which sensor provides data for the measurement. The same source is used for all of a tool's
measurements.
Depending on the layout you have selected, the Source drop-down will display one of the following (or a
combination). For more information on layouts, see System Layout on page 71.
The Source setting applies to all of a tool's measurements.