Gocator Line Profile Sensors: User Manual
Protocols 395
Field Type Offset Description
0 General failure
-1 No data in the field of view for stationary alignment
-2 No profiles with sufficient data for line fitting for travel
alignment
-3 Invalid target detected. Examples include:
- Calibration disk diameter too small.
- Calibration disk touches both sides of the field of view.
- Too few valid data points after outlier rejection.
-4 Target detected in an unexpected position.
-5 No reference hole detected in bar alignment.
-6 No change in encoder value during travel calibration
-988 User aborted
-993 Timed out
-997 Invalid parameter
Exposure Calibration Result
Field Type Offset Description
size 32u 0 Count of bytes in message (including this field).
control 16u 4 Bit 15: Last message flag.
Bits 0-14: Message type identifier. For this message, set to 12.
attributesSize 16u 6 Size of attributes, in bytes (min: 12, current: 12).
opId 32u 8
Operation ID.
status 32s 12 Operation status.
exposure 32s 16 Exposure result (ns).
Edge Match Result
Field Type Offset Description
size 32u 0 Count of bytes in message (including this field).
control 16u 4 Bit 15: Last message flag.
Bits 0-14: Message type identifier. For this message, set to 16.
decision byte 6 Overall match decision.
xOffset 32s 7 Target x offset in model space (µm).
yOffset 32s 11 Target y offset in model space (µm).
zAngle 32s 15 Target z rotation in model space (microdegrees).
quality 32s 19 Match quality (thousandth).
qualityDecision byte 23 Quality match decision.
reserved[2] byte 24 Reserved.