Gocator Line Profile Sensors: User Manual
Gocator Web Interface 121
Edge Filtering enabled, Preserve Interior Feature enabled
To configure edge filtering:
1. Go to the Scan page and choose Surface in the Scan Mode panel.
If this mode is not selected, you will not be able to configure part detection.
2. Expand the Part Detection panel by clicking on the panel header or the button and enable part
detection if necessary.
Part detection can be enabled and disabled when Type in the Surface Generation panel is set to Fixed
Length, Variable Length, or Rotational. Part detection is automatically enabled when Type is set to
Continuous.
3. Check the Edge Filtering checkbox to enable edge filtering.
4. Configure the Width and Length settings.
The Width and Length settings represent the size of the filter on the X axis and the Y axis, respectively.
5. Set the Preserve Interior Feature setting if necessary.
The Preserve Interior Feature setting limits filtering to the outside edges of the target.
Data Viewer
The data viewer can display video images, , profiles, sections, surfaces, height maps, and intensity
images. It is also used to configure the active area (see on page 94) and measurement tools (see on page
155). The data viewer changes depending on the current operation mode and the panel that has been
selected.