Gocator Line Profile Sensors: User Manual
Gocator Emulator • 263
3. Click the button next to the scenario you want to remove.
The scenario is removed from the emulator.
Using Replay Protection
Making changes to certain settings on the Scan page causes the emulator to flush replay data. The
Replay Protection option protects replay data by preventing changes to settings that affect replay
data. Settings that do not affect replay data can be changed.
If you try to uncheck Replay Protection, you must confirm that you want to disable it.
Replay Protection is on by default.
Stopping and Restarting the Emulator
To stop the emulator:
l
Click Stop Emulation.
Stopping the emulator returns you to the launch screen.
To restart the emulator when it is running:
l
Click Restart Emulation.
Restarting the emulator restarts the currently running simulation.
Working with Jobs and Data
The following topics describe how to work with jobs and replay data (data recorded from a physical
sensor)in the emulator.
Creating, Saving, and Loading Jobs
Changes saved to job files in the emulator are not persistent (they are lost when you close or restart the
emulator). To keep jobs permanently, you must first save the job in the emulator and then download the
job file to a client computer. See below for more information on creating, saving, and switching jobs. For