Gocator Line Profile Sensors: User Manual
Gocator Device Files • 337
Element Type Description
0 – Disable
1 – Enable
HoldEnabled Boolean
Output hold enable state:
0 – Disable
1 – Enable
SmoothingEnabled Boolean
Smoothing enable state:
0 – Disable
1 – Enable
SmoothingWindow 32u Smoothing window.
Scale 64f Output scaling factor.
Offset 64f Output offset factor.
DecisionMin 64f Minimum decision threshold.
DecisionMax 64f Maximum decision threshold.
RadiusOffset
(Radius measurement only)
64f Radius offset of the stud.
SurfaceVolume
A SurfaceVolume element defines settings for a surface volume tool and one or more of its
measurements.
Element Type Description
Name String Tool name.
Source 32s Surface source.
Anchor\X String (CSV) The X measurements (IDs) used for anchoring.
Anchor\X.options String (CSV) The X measurements (IDs) available for anchoring.
Anchor\Y String (CSV) The Y measurements (IDs) used for anchoring.
Anchor\Y.options String (CSV) The Y measurements (IDs) available for anchoring.
Anchor\Z String (CSV) The Z measurements (IDs) used for anchoring.
Anchor\Z.options String (CSV) The Z measurements (IDs) available for anchoring.
StreamOptions Collection
A collection of StreamOption on page 299 elements.
Stream\Step
32s The stream source step. Possible values are:
1 – Video
2 – Range
3 – Surface
4 – Section
Stream\Id 32u The stream source ID.
SurfaceVolume Child Elements