Gocator Line Profile Sensors: User Manual
Gocator Web Interface 166
Removing a Tool
Removing a tool removes all of its associated measurements.
To remove a tool:
1. Go to the Scan page by clicking on the Scan icon.
2. Choose Profile or Surface mode in the Scan Mode panel.
If is not selected, tools will not be available in the Measure panel.
3. Go to the Measure page by clicking on the Measure icon.
4. In the tool list, click on the button of the tool you want to delete.
The tool will be removed from the tool list.
Profile Measurement
This section describes the profile measurement tools available in Gocator sensors.
When Gocator is in Surface mode and you have defined a section, a Stream option displays in Profile
tools.
Thefollowing tools are available when UniformSpacing is disabled:
l Bridge Value
l Dimension
l Position
l Script
For more information on the Uniform Spacing setting and resampled data, see Uniform Spacing (Data
Resampling) on page 53.
Profile measurement tools can be used on sections. For more information on sections, see Sections on
page 149.
Feature Points
Most measurements detect and compare feature points or lines found within laser profile data.
Measurement values are compared against minimum and maximum thresholds to yield decisions.
The following types of points can be identified.
Point Type Examples
Max Z
Finds the point with the maximum Z value in the region of
interest.