Gocator Line Profile Sensors: User Manual
Protocols 394
Field Type Offset Description
poseAngle 32s 33 Z angle of the pose (microdegrees).
poseX 32s 37 X offset of the pose (µm).
poseY 32s 41 Y offset of the pose (µm).
points[C][W] 8u 45 Intensity arrays.
Measurement
Field Type Offset Description
size 32u 0 Count of bytes in message (including this field).
control 16u 4 Bit 15: Last message flag.
Bits 0-14: Message type identifier. For this message, set to 10.
count (C) 32u 6 Count of measurements in this message.
reserved[2] 8u 10 Reserved.
id 16u 12 Measurement identifier.
measurements[C] Measurement 14 Array of measurements (see below).
Field Type Offset Description
value 32s 0 Measurement value.
decision 8u 4 Measurement decision bitmask.
Bit 0:
1 Pass
0 Fail
Bits 1-7:
0 Measurement value OK
1 Invalid value
2 Invalid anchor
reserved[3] 8u 5 Reserved.
Measurement
Operation Result
Field Type Offset Description
size 32u 0 Count of bytes in message (including this field).
control 16u 4 Bit 15: Last message flag.
Bits 0-14: Message type identifier. For this message, set to 11.
attributesSize 16u 6 Size of attributes, in bytes (min: 8, current: 8).
opId 32u 8 Operation ID.
status 32s 12 Operation status.
1 OK