Gocator Line Profile Sensors: User Manual
Gocator Web Interface • 211
Parameter Description
Tilt Correction Tilt of the target with respect to the alignment plane.
When this option is set to Autoset, the tool automatically detects the
tilt. Otherwise, the user must enter the angles manually. Autoset
requires the measurement region to cover more areas on the surface
plane than other planes.
The results from the Plane X and Y tool can be used for angles X and Y
parameters.
Partial Detection Enable if only part of the hole is within the measurement region. If
disabled, the hole must be completely in the region of interest for
results to be valid.
Plane Fit Range Excludes data beyond the specified distance from the plane
surrounding the hole. You can use this setting to exclude surfaces
close to the countersunk hole that step down from the plane
surrounding the hole that could make measurement of the hole less
reliable.
Decision See Decisions on page 159.
Region See Regions on page 158.
Output See Filters on page 161.
Dimension
The Dimension tool returns various dimensional measurements of a part. You must specify two feature
types (see below).
Gocator compares the measurement value with the values in Min and Max to yield a decision. For more
information on decisions, see Decisions on page 159.
See Adding and Configuring a Tool on page 156 for instructions on how to add measurement tools.
2DView 3DView