Element Type Description
1 AND of measurements is false
2 Always assert
Delay 64f Output delay (µs or mm, depending on delay domain defined below).
DelayDomain 32s
Output delay domain:
0 Time (µs)
1 Encoder (mm)
Inverted Bool Whether the sent bits are flipped.
Measurements 32u (CSV) Selected measurement sources.
Measurements.options 32u (CSV) List of available measurement sources.
Analog
The Analog element defines settings for analog output.
The range of valid measurement values [DataScaleMin, DataScaleMax] is scaled linearly to the specified
current range [CurrentMin, CurrentMax].
Only one Value or Decision source can be selected at a time.
Element Type Description
Event 32s
Triggering event:
0 None (disabled)
1 Measurements
2 Software
ScheduleEnabled Bool Enables scheduling.
CurrentMin 64f Minimum current (mA).
CurrentMin.min 64f Minimum value of minimum current (mA).
CurrentMin.max 64f Maximum value of minimum current (mA).
CurrentMax 64f Maximum current (mA).
CurrentMax.min 64f Minimum value of maximum current (mA).
CurrentMax.max 64f Maximum value of maximum current (mA).
CurrentInvalidEnabled Bool Enables special current value for invalid measurement value.
CurrentInvalid 64f Current value for invalid measurement value (mA).
CurrentInvalid.min 64f Minimum value for invalid current (mA).
CurrentInvalid.max 64f Maximum value for invalid current (mA).
DataScaleMin 64f Measurement value corresponding to minimum current.
DataScaleMax 64f Measurement value corresponding to maximum current.