Gocator Line Profile Sensors: User Manual
Gocator Device Files • 312
Element Type Description
0 – Disable
1 – Enable
SmoothingEnabled Boolean
Smoothing enable state:
0 – Disable
1 – Enable
SmoothingWindow 32u Smoothing window.
Scale 64f Output scaling factor.
Offset 64f Output offset factor.
DecisionMin 64f Minimum decision threshold.
DecisionMax 64f Maximum decision threshold.
Absolute
(Angle measurement only)
Boolean
Setting for selecting the angle range:
0 – A range of -90 to 90 degrees is used.
1 – A range of 0 to 180 degrees is used.
ProfileLine
A ProfileLine element defines settings for a profile line tool and one or more of its measurements.
Element Type Description
Name String Tool name.
Source 32s Profile source.
Anchor\X String (CSV) The X measurements (IDs) used for anchoring.
Anchor\X.options String (CSV) The X measurements (IDs) available for anchoring.
Anchor\Z String (CSV) The Z measurements (IDs) used for anchoring.
Anchor\Z.options String (CSV) The Z measurements (IDs) available for anchoring.
StreamOptions Collection
A collection of StreamOption on page 299 elements.
Stream\Step
32s The stream source step. Possible values are:
1 – Video
2 – Range
3 – Surface
4 – Section
Stream\Id 32u The stream source ID.
RegionEnabled Bool Whether or not to use the region. If the region is disabled,
all available data is used.
Region
ProfileRegion2d
Measurement region.
Measurements\StdDev Line tool
measurement
StdDev measurement.
Measurements\MaxError Line tool MaxError measurement.
ProfileLine Child Elements