Gocator Device Files 341
Element Type Description
2 Top left
3 Top right
ProfileIntensities.options 32s (CSV) List of available profile intensity sources (see above).
SurfaceIntensities 32s (CSV)
Selected surface intensity sources:
0 Top
1 Bottom
2 Top left
3 Top right
SurfaceIntensities.options 32s (CSV) List of available surface intensity sources (see above).
Measurements 32u (CSV) Selected measurement sources.
Measurements.options 32u (CSV) List of available measurement sources.
Events 32s (CSV)
CSV list of possible event options:
0 Exposure Begins
1 Exposure Ends
Events.options 32s (CSV) List of available event options (see above).
Ascii
Element Type Description
Operation 32s Operation mode:
0 Asynchronous
1 Polled
ControlPort 32u Control service port number.
HealthPort 32u Health service port number.
DataPort 32u Data service port number.
Delimiter String Field delimiter.
Terminator String Line terminator.
InvalidValue String String for invalid output.
CustomDataFormat String Custom data format.
CustomFormatEnabled Bool Enables custom data format.
StandardFormatMode 32u
The formatting mode used if not a custom format:
0 Standard
1 Standard with Stamp