Gocator Device Files 339
For all sub-elements, the source identifiers used for measurement outputs correspond to the
measurement identifiers defined in each tool's Measurements element. For example, in the following
XML, in the options attribute of the Measurements element, 2 and 3 are the identifiers of measurements
that are enabled and available for output. The value of the Measurements element (that is, 2) means
that only the measurement with id 2(Profile Dimension Width) will be sent to output.
<ProfileDimension> ...
<Measurements>
<Width id="2"> ...
<Height id="3"> ...
<Output>
<Ethernet> ...
<Measurements options="2,3">2</Measurements>
Ethernet
The Ethernet element defines settings for Ethernet output.
In the Ethernet element, the source identifiers used for video, range, profile, and surface output, as well
as range, profile, and surface intensity outputs, correspond to the sensor that provides the data. For
example, in the XMLbelow, the options attribute of the Profiles element shows that only two sources are
available (see the table below for the meanings of these values). The value in this element—0—indicates
that only data from that source will be sent to output.
<Output>
<Ethernet>
...
<Ranges options=""/>
<Profiles options="0,1">0</Profiles>
<Surfaces options=""/>
...
Element Type Description
Protocol 32s
Ethernet protocol:
0 Gocator
1 Modbus
2 EtherNet/IP
3 ASCII
TimeoutEnabled Boolean Enable or disable auto-disconnection timeout. Applies only to the
Gocator protocol.
Timeout 64f Disconnection timeout (seconds). Used when TimeoutEnabled is true and
the Gocator protocol is selected.
Ethernet Child Elements

Table of Contents